Operating fireplace – Desa VMH10TPC User Manual

Page 26

Advertising
background image

www.desatech.com

112462-01F

26

OPERATING FIREPLACE

Continued

D. Do not use this appliance if any part has

been under water. Immediately call a

qualified service technician to inspect the

appliance and to replace any part of the

control system and any gas control which

has been under water.

LIGHTING

INSTRUCTIONS

WARNING: You must operate

this fireplace with the fireplace

screen in place. Make sure fire-

place screen is installed before

running fireplace.

NOTICE: During initial operation

of new fireplace, burning logs will

give off a paper-burning smell.

Open window to vent smell. This

will only last a few hours.

WARNING: Burner will come

on automatically within one min-

ute when control valve is in the

ON position after the pilot is lit.

1. STOP! Read the safety information, page 25.

2. Make sure equipment shutoff valve is fully

open.

3. Press in and turn control knob clockwise

to the OFF position (see Figure 39).

4. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information, column 2, page 25. If

you donʼt smell gas, go to the next step.

5. Press in and turn control knob counter-

clockwise

to the PILOT position.

Press in control knob for five (5) seconds

(see Figure 39).

Note:

You may be running this fireplace for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

6. With control knob pressed in, press and

release electronic ignitor button. This will

light pilot. The pilot is attached to the front

of the burner. If needed, keep pressing

ignitor button until pilot lights.

Note:

If pilot does not stay lit, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure, page 27.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop out when

released, contact a qualified service person

or gas supplier for repairs.

Note:

If pilot goes out, repeat steps 4

through 8.

8. Slightly push in and turn control knob coun-

terclockwise

to the ON position.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Figure 39 - Control Knob and Ignitor

Button Location (Shown as Supplied

- No Control Options)

Control Knob

Electronic Ignitor

Figure 40 - Propane/LP Gas Pilot

Ignitor
Electrode

Pilot
Burner

Figure 41 - Natural Gas Pilot

Ignitor
Electrode

Pilot Burner

Advertising