Specifications, Wiring diagram, Service hints – Desa VMH10TPC User Manual

Page 35: Technical service, Replacement parts, Specifications service hints

Advertising
background image

www.desatech.com

112462-01F

35

SPECIFICATIONS

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• for propane/LP units, propane/LP gas supply

may be low

You may feel your gas pressure is too low. If so, con-

tact your local natural or propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation,

operation or troubleshooting. If so, contact DESA

Heating Productsʼ Technical Service Department at

1-866-672-6040. When calling, please have your

model and serial numbers of your heater ready.
You can also visit DESA Heating Productsʼ techni-

cal services web site at

www.desatech.com

.

REPLACEMENT PARTS

Note:

Use only original replacement parts. This

will protect your warranty coverage for parts

replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If

they canʼt supply original replacement part(s),

call DESA Heating Productsʼ Technical Service

Department at 1-866-672-6040.
When calling DESA Heating Products, have ready
• your name
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the

factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they

canʼt supply original replacement part(s), call

DESA Heating Products at 1-866-672-6040 for

referral information.
When calling DESA Heating Products, have ready
• model number of your fireplace
• the replacement part number

WIRING DIAGRAM

(REMOTE-READY MODELS ONLY)

Red

Jumper Wire

White

Thermopile

Gas Control

TPTH

TH

TPTH TP

EFS10TPA, VMH10TPC
• Rating: 10,000 Btu/Hr
• Gas Type: Propane/LP

Ignition: Electronic Ignitor

• Manifold Pressure: 8.5" W.C.
• Inlet Gas Pressure (in. of water):

Maximum - 14", Minimum* - 11"
EFS10RPA, CGCF10PR, VMH10RPC
• Rating: 10,000 Btu/Hr
• Gas Type: Propane/LP

Ignition: Electronic Ignitor

• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water):

Maximum - 14", Minimum* - 11"
* For purpose of input adjustment

EFS10TNA, VMH10TNC
• Rating: 10,000 Btu/Hr
• Gas Type: Natural

Ignition: Electronic Ignitor

• Manifold Pressure: 3" W.C.
• Inlet Gas Pressure (in. of water):

Maximum - 10.5", Minimum* - 5"
EFS10RNA, CGCF10NR, VMH10RNC
• Rating: 10,000 Btu/Hr
• Gas Type: Natural

Ignition: Electronic Ignitor

• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water):

Maximum - 10.5", Minimum* - 5"
* For purpose of input adjustment

ALL MODELS
• Dimensions (HxWxD): Fireplace (including hood and screws) - 25

7

/

8

" x 26

13

/

16

" x 9

3

/

8

",

Carton - 32

5

/

8

" x 27

13

/

16

" x 11

5

/

8

"

• Weight: Fireplace - 44.5 lbs., Shipping: 48 lbs.

Advertising
This manual is related to the following products: