Installation – Desa VMH10TPC User Manual

Page 12

Advertising
background image

www.desatech.com

112462-01F

12

3. Install gas piping to fireplace location. This

installation includes an approved flexible gas

line (if allowed by local codes) after the equip-

ment shutoff valve. The flexible gas line must

be the last item installed on the gas piping.

4. If you have not assembled firebox, follow

instructions on page 6.

5. Carefully set fireplace in front of rough opening

with back of fireplace inside wall opening.

6. Attach flexible gas line to fireplace gas regula-

tor. See Connecting Fireplace to Gas Supply,

page 19.

7. Bend four nailing flanges on outer casing with

pliers (see Figure 9).

8. Attach fireplace to wall studs using nails

or wood screws through holes in nailing

flange.

9. Check all gas connections for leaks. See

Checking Gas Connections, page 19.

10. If using optional trim kit, install the trim after

final finishing and/or painting of wall. See

instructions included with trim accessory for

attaching trim.

IMPORTANT:

When finishing your firebox,

combustible materials such as wall board, gypsum

board, sheet rock, drywall, plywood, etc. may be

butted up next to the sides and top edge of the fire-

box. Combustible materials should never overlap

the firebox front facing.

INSTALLATION

Continued

Figure 9 - Attaching Fireplace to Wall

Studs

Nailing

Flanges

Nails or

Wood

Screws

Wall

Studs

WARNING: Do not allow any

combustible or noncombustible

materials to overlap the firebox

front facing.

WARNING: Do not allow

noncombustible materials to

cover any necessary openings

like louvered slots.

WARNING: Never modify or

cover the louvered slots on the

front of the firebox.

Mantel Clearances for Built-In
Installation
If placing mantel above built-in fireplace, you must

meet minimum clearance between mantel shelf and

top of fireplace opening.

NOTICE: Surface temperatures

of adjacent walls and mantels

become hot during operation.

Walls and mantels above the

firebox may become hot to

the touch. If installed properly,

these temperatures meet the

requirement of the national

product standard. Follow all

minimum clearances shown in

this manual.

NOTICE: If your installation

does not meet the minimum

clearances shown in Figure 10,

page 13, you must do one of the

following:

• raise the mantel to an accept-

able height

• remove the mantel

Advertising
This manual is related to the following products: