Smartsensor matrix package – Wavetronix SmartSensor Matrix (SS-225) - User Guide User Manual

Page 7

Advertising
background image

6

INTRODUCTION SMARTSENSOR MATRIX USER GUIDE

ration process is quick and easy. After installation, the sensor will require little or no on-site

maintenance and can be remotely configured.

This user guide outlines the step-by-step process of installing and configuring the Smart-

Sensor Matrix. Any questions about the information in this guide should be directed to

Wavetronix or your distributor.

SmartSensor Matrix Package

A standard SmartSensor Matrix package may contain some combination of the following items:

˽

SmartSensor Matrix detector(s) with installed sensor backplate

˽

Sensor mounting kit(s)

˽

SmartSensor 6-conductor cable(s)

˽

Intersection preassembled backplate, Click 650 cabinet interface device or Click 600

cabinet interface device

˽

Click 112/114 detector rack card(s) with patch cable(s)

˽

Click 104 four-channel DIN rail contact closure module

˽

SmartSensor Manager Matrix (SSMM) software

˽

SmartSensor Matrix User Guide

Note

In addition to the intersection preassembled backplate and the Click 600/650 cabi-
net interface devices, you could also use the preassembled 19-inch rack or the seg-
mented preassembled backplate. The coming chapters will discuss the differences
between and uses of these various cabinet solutions.

SmartSensor Matrix installations should perform the following functions for the sensor:

˽

AC power conversion – Provides reliable power for the sensors and other components.

This option is normally recommended instead of the DC surge protection because it

will not burden the existing DC power modules.

˽

Surge protection – Protects equipment from surges coming from the power source or

from a cable run.

˽

Remote IP connection – Provides a way (via a Click 301 serial to Ethernet converter, or

onboard Ethernet capabilities) to connect to the sensor from a remote location.

Figure I.2 shows several possible installation setups; these connect the sensor to a controller

by way of the Click 650, the Click 600 or a preassembled backplate. Some of these solutions

also require the use of contact closure cards in an input file rack.

Advertising