Westermo ED-10 TCP User Manual

Page 12

Advertising
background image

12

6609-2211

CH2: RS-232 Connections (D-sub connector), DCE

CH1 and CH2 are not galvanic isolated.

Please use a RS-232 isolator (e.g. MD-52) if earth voltage differences are suspected. An isolator on
permanently connected CH2, is required to maintain the enhanced transient/surge protection of CH1.

5

4

3

2

1

9

8

7

6

Pin

Signal Name*

Number Description

V.24

RS-232C

Direction**

Description

1

DCD

109

CF

Data Carrier Detect, not connected

2

RD

104

BB

Out

Received Data

3

TD

103

BA

In

Transmitted Data

4

DTR

108.2

CD

Data Terminal Ready, not connected

5

SG

102

AB

In/out

Signal Ground

6

DSR

107

CC

Data Set Ready, not connected

7

RTS

105

CA

In

Request to Send, not used

8

CTS

106

CB

Out

Clear to Send, not used

9

RI

125

CE

Ring Indicator, not connected

* Functionality might differ from standard, see chapter 7.3

** Direction relative ED-10 TCP.

RS-232 cable must not exceed 15 m

Ethernet 10Base-T Connection (RJ-45 connector),
straight function MDI (no crossover)

Contact

Signal Name

Direction*

Description

1

TD+

Out

Transmitted Data

2

TD–

Out

Transmitted Data

3

RD+

In

Received Data

4

Not connected

5

Not connected

6

RD–

In

Received Data

7

Not connected

8

Not connected

* Direction relative ED-10 TCP.

CAT 5 cable is recommended.
Unshielded (UTP) or shielded (STP) connector might be used.

8

7

6

5

4

3

2

1

Advertising