96

Figure 42 User logging 3.0 log report

Table 23 User logging 1.0 field description

Item Description

Time/Date

Time and date when a user log was generated.

Protocol Type

Protocol type of a flow log.

Flow Information

Flow information:

•

If the protocol type is TCP or UDP, the displayed flow information is source IP

address:source port-->destination IP address:destination port, for example,

1.1.1.2:1026-->1.1.2.10:69.

•

If the protocol type is another type except TCP or UDP, the displayed flow

information is source IP address-->destination IP address, for example,
1.1.1.2-->1.1.2.10.

Start Time

Time when a flow was created.

End Time

Time when a flow was removed.

Flow Action

Operator field of a flow:

•

(1)Normal over—The flow ended normally.

•

(2)Aged for timeout—Timer timed out.

•

(3)Aged for reset or config-change—Flow aging due to configuration change.

•

(4)Aged for no enough resource—Flow aging due to insufficient resource.

•

(5)Aged for no-pat of NAT—One to one NAT. In this case, only the source IP

address, the source IP address after translation and the time fields are available.

•

(6)Active data flow timeout—The life time of the flow reached the limit.

•

(8)Data flow created—Record for the flow when it was created.

•

(254)Other—Other reasons.

Table 24 User logging 3.0 field description

Item Description

Time/Date

Time and date when a user log was generated.

Protocol Type

Protocol type of a flow.