Grass Valley iTX System v.2.6 User Manual

Page 284

Advertising
background image

Using iTX Desktop layouts for system administration

4.

If you want the generated name to include a number that increments with each new name,

do the following.

•

In the Rule Elements list, expand the Sequence category; click Sequence; click

to

display the Choose A Sequence To Use dialog.

•

Select a sequence; click OK to close the dialog.

The sequence appears in the Current Rule list. The Preview box displays a sample name,

resulting from the rule in its current state.
Note: You can create sequences in the sequence-management panel. See later in this

section, “Create a sequence for an automatically generated name”.

5.

If you want the generated name to include text entered by an operator at the time the

OPUS 2 Service creates the name, do the following.

•

In the Rule Elements list, expand the Text category; click Parameter: INPUT; click

to

display the Text Parameter Properties dialog.

•

In the Text ID box, enter the text label you want to appear on the Rule Text Parameter

component – the iTX Desktop component that enables an operator to insert text in the

automatically generated name.

•

In the Character Mask box, enter characters that you do not want the operator to be

able to use (e.g. punctuation marks).

•

In the Text Length box, specify the maximum permissible number of characters in the

operator text entry.

•

Leave the Padding button unselected (a red “x” is displayed) and the Padding Text box

empty.

•

Click OK to close the dialog.

The rule element appears in the Current Rule list. The Preview box displays a sample name,

resulting from the rule in its current state.

6.

If you want to re-position any of the rule elements in the Current Rule list, click its name

and then either

or

.

7.

If you want to remove any of the rule elements from the Current Rule list, click its name

and then

.

Create a sequence for an automatically generated name

When the same sequence appears in multiple naming rules, the sequence increments each

time the OPUS 2 Service creates a name based on any of these rules. So, the names it creates

for any one rule may not form a continuous series.

For example: If one rule includes fixed text “abc” and another includes fixed text “xyz”, and

both use the same sequence, the OPUS 2 Service may generate a set of names like this: abc001,

abc002, xyz003, abc004, xyz005.

If you do not want different naming rules to share a sequence, you may create a new sequence

(instead of using an existing one) when you include a Sequence element in a naming rule.

To create, edit or delete a sequence, you use the features in the sequence-management panel

on the Naming Rule Administrator:

March 2015

System Administrator Guide

Page 284 of 404

Advertising
This manual is related to the following products: