Spindle status: q110, Coolant on/off: q111, Overlap factor: q112 – HEIDENHAIN iTNC 530 (340 49x-01) ISO programming User Manual
Page 452: Tool length: q114

452
10 Programming: Q Parameters
1
0
.9 Pr
eassigned Q P
a
ra
met
e
rs
Spindle status: Q110
The value of Q110 depends on which M function was last
programmed for the spindle:
Coolant on/off: Q111
Overlap factor: Q112
The overlap factor for pocket milling (MP7430) is assigned to Q112.
Unit of measurement for dimensions in the
program: Q113
The value of parameter Q113 specifies whether the highest-level NC
program (for nesting with %...) is programmed in millimeters or
inches.
Tool length: Q114
The current value for the tool length is assigned to Q114.
M Function
Parameter value
No spindle status defined
Q110 = –1
M03: Spindle ON, clockwise
Q110 = 0
M04: Spindle ON, counterclockwise
Q110 = 1
M05 after M03
Q110 = 2
M05 after M04
Q110 = 3
M Function
Parameter value
M08: Coolant ON
Q111 = 1
M09: Coolant OFF
Q111 = 0
Dimensions of the main program
Parameter value
Metric system (mm)
Q113 = 0
Inch system (inches)
Q113 = 1