5.3 Connection to the Power Distribution Grid (AC)

5.3.1 Conditions for the AC Connection

Cable Design

Use "Sunny Design" version 2.0 or higher for the dimensioning of the conductor cross-sectional areas
(see "Sunny Design" design program at www.SMA.de/en).

Cable Requirements

Connection requirements of the grid operator
Always observe the connection requirements of your grid operator.

Position

Designation

Value

A

External diameter

6 mm ... 14 mm

B

Conductor cross-section

4 mm²

C

Length of insulation to be stripped off

8 mm