Technical Data

SMA Solar Technology AG

70

SB33-38-11-IA-en-62

Installation Manual

11.2.5 Electronic Solar Switch (optional)

11.2.6 Torque

11.2.7 Distribution Systems

Electrical endurance in the event of a short
circuit, with a nominal current of 30 A

at least 50 switching processes

Maximum switching current

30 A

Maximum switching voltage

800 V

Maximum PV power

10 kW

Degree of protection when plugged

IP65

Degree of protection when unplugged

IP21

Enclosure lid screws

6.0 Nm

Additional grounding screws

6.0 Nm

Cheese-head screws for securing the enclosure
to the wall mounting bracket

6.0 Nm

SUNCLIX swivel nut

2 Nm

RS485 communication connection

1.5 Nm

IT system

suitable

TN-C system

suitable

TN-S system

suitable

TN-C-S system

suitable

TT system

suitable

Split-phase

tsuitable