Ethernet/ip option kit cm092 – Yaskawa CM092 User Manual

Page 6

Advertising
background image

Yaskawa America, Inc. –

www.yaskawa.com

IG.AFD.26, Page 6 of 16

Date: 08/18/2011 Rev: 11-08

EtherNet/IP Option Kit

CM092

17. Drive labeling and EDS files

18. EtherNet/IP Option Card fault codes

a. Place the supplied MAC ID label on the side of the drive either above or below the drive nameplate.

Nameplate for all drives except G5HHP drives Nameplate for G5HHP drives

b. To simplify the drive configuration, EDS file can be obtained at

www.yaskawa.com

. Select Downloads, By Inverter Drives, By Product, and Network

Comms-Ethernet. Then select the appropriate EDS file based on the drive series and the latest version from those listed. EDS files for individual drive
models are compressed into a single Zip file.

MODEL:

CIMR-G7U20P4

SPEC: 20P41A

INPUT: AC3PH 200 - 240V 50/60Hz 3.8A
OUTPUT: AC3PH 0 - 240V 0 – 400Hz 3.2A 1.2kVA
O/N:

MASS: 3.0kg

S/N:

1W0149999991W0001

PRG:

1W0149999991W0001
FILE NO: E131457

MAC ID: 00-20-B5-24-11-13

INVERTER MODULE

CODE NO.: EUJ615162
SERV. NO.: 4W06X7847760001

MASS:

125KG

YASKAWA AMERICA, INC.

MAC ID: 00-20-B5-24-11-13

The table of EtherNet/IP Option Card fault codes returned by the drive is shown below. Refer to the appropriate drive user and/or programming manual(s) for drive
specific information on the fault returned.

Note: G5HHP drive differences are denoted by bold text inside carets <> in the following table.

EtherNet/IP Fault Code

[hex]

Description

EtherNet/IP

Fault Code

[hex]

Description

0000h

None

5300h

OPE errors (01,02,03,05,06,07,08,09,10,11)

2120h

Ground Fault (GF)

6320h

EEPROM R/W Error (ERR)

2130h

Short Circuit (SC)

7110h

Dynamic Braking Transistor (RR) <Reserved>

2200h

Inverter Overload (OL2)

7112h

Dynamic Braking Resistor (RH) <Reserved>

2220h

Motor Overload (OL1)

7301h

PG Open (PGO)

2221h

Overtorque Detection 1 (OL3)

7310h

Overspeed Detection (OS)

2222h

Overtorque Detection 2 (OL4)

7310h

Speed Deviation (DEV)

2300h

Overcurrent (OC)

7500h

EtherNet/IP Communication Error (BUS)

2310h

High Slip Braking (OL7)

<Reserved>

8110h

Feedback Loss (FBL)

3130h

Input Phase Loss (PF)

8313h

Zero Servo Fault (SVE)

3130h

Output Phase Loss (LF)

8321h

Out of Control (CF)

3210h

DC Bus Overvoltage (OV)

8321h

Undertorque Detection 1 (UL3)

3220h

DC Bus Undervoltage (UV1)

8321h

Undertorque Detection 2 (UL4)

3222h

MC Answerback (UV3)

9000h

External Fault on Terminal S3 (EF3) <External Fault 3 (EF3) (Terminal 11)>

4200h

Heatsink Over-temperature (OH)

9000h

External Fault on Terminal S4 (EF4) <External Fault 4 (EF4) (Terminal 12)>

4210h

Heatsink Maximum Temperature

(OH1)

9000h

External Fault on Terminal S5 (EF5) <External Fault 5 (EF5) (Terminal 13)>

4300h

Motor Overheat 1 (OH3)

9000h

External Fault on Terminal S6 (EF6) <External Fault 6 (EF6) (Terminal 14)>

4310h

Motor Overheat 2 (OH4)

9000h

External Fault on Terminal S7 (EF7) <External Fault 7 (EF7) (Terminal 15)>

5110h

CTL PS Undervoltage (UV2)

9000h

External Fault on Terminal S8 (EF8) <External Fault 8 (EF8) (Terminal 16)>

5120h

DC Bus Fuse Open (PUF)

9000h

External Fault Through Option Card (EF0)

5300h

Operator Disconnected (OPR)

-

-

Advertising