EtherNet/IP Option Kit

CM092

EtherNet/IP Option Card
Supported Class Summary

Supported Output Instances for Assembly

Object Class 04

Note: G5HHP drive differences are denoted by bold text
inside carets <> in the following tables.

♦ Basic Speed Control Output Instance 20 (14h)

♦ Extended Speed Control Output Instance 21 (15h)

♦ Speed and Torque Control Output Instance 22 (16h)

♦ Extended Speed and Torque Control Output Instance 23 (17h)

01 – Identity Object
02 – Message Router Object
04 – Assembly Object

06 – Connection Manager Object
28 – Motor Object
29 – Control Supervisor Object

2A – AC Drive Object
64 – Yaskawa Command Object
65 – Yaskawa Status Object

F5 – TCP/IP Object
F6 – Ethernet Link Object

Output

Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

20 (14h)

0h

-

-

-

-

-

Fault Reset

-

Run Forward

1h

Reserved

2h

Speed Reference (Low Byte) [Scaled by parameter o1-03] [U1-01]

3h

Speed Reference (High Byte) [Scaled by parameter o1-03] [U1-01]

Output

Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

21 (15h)

0h

-

Net Reference

<Not Available>

Net Run/Stop

<Not Available>

-

-

Fault Reset

Run Reverse

Run Forward

1h

Reserved

2h

Speed Reference (Low Byte) [Scaled by parameter o1-03] [U1-01]

3h

Speed Reference (High Byte) [Scaled by parameter o1-03] [U1-01]

Output

Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

22 (16h)

0h

-

-

-

-

-

Fault Reset

-

Run Forward

1h

Reserved

2h

Speed Reference (Low Byte) [Scaled by parameter o1-03] [U1-01]

3h

Speed Reference (High Byte) [Scaled by parameter o1-03] [U1-01]

4h

Torque Reference (Low Byte) [0.1%] [U1-09]

5h

Torque Reference (High Byte) [0.1%] [U1-09]

Output

Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

23 (17h)

0h

-

Net Reference

<Not Available>

Net Run/Stop

<Not Available>

-

-

Fault Reset

Run Reverse

Run Forward

1h

Reserved

2h

Speed Reference (Low Byte) [Scaled by parameter o1-03] [U1-01]

3h

Speed Reference (High Byte) [Scaled by parameter o1-03] [U1-01]

4h

Torque Reference (Low Byte) [0.1%] [U1-09]

5h

Torque Reference (High Byte) [0.1%] [U1-09]