Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Digi
tal i
nputs Terminal S7 Function
Selection
H1-05
6 (4)
H1-07*
5 (F)
F7 L1000A
25: External fault (N.C., 
Always detected, Coast to 
stop) 
25: External fault (N.C., 
Always detected, Coast to 
 stop) 
26: External fault (N.O., 
Detected during run, Coast 
to stop) 
26: External fault (N.O., 
Detected during run, Coast 
to stop) 
27: External fault (N.C., 
Detected during run, Coast 
to stop) 
27: External fault (N.C., 
Detected during run, Coast 
to stop) 
28: External Fault (N.O., 
always detected, Fast Stop) 
28: External Fault (N.O., 
always detected, Fast Stop)
29: External fault (N.C., 
always detected, Fast Stop) 
29: External fault (N.C., 
always detected, Fast Stop)
2A: External Fault (N.O., 
detected during run, Fast 
Stop) 
2A: External Fault (N.O., 
detected during run, Fast 
Stop) 
2B: External fault (N.C., 
detected during run, Fast 
Stop) 
2B: External fault (N.C., 
detected during run, Fast 
Stop) 
2C: External fault (N.O., 
always detected, alarm 
only) 
2C: External fault (N.O., 
always detected, alarm 
only) 
2D: External fault (N.C., 
always detected, alarm 
only) 
2D: External fault (N.C., 
always detected, alarm 
only) 
Digi
tal Inpu
ts
Terminal S8 Function 
Selection 
H1-06 8
(6) H1-08
F
F7 L1000A
2E: External Fault 
(N.O., detected during run, 
alarm only) 
2E: External Fault (N.O., 
detected during run, alarm 
only) 
2F: External Fault (N.C., 
detected during run, alarm 
only) 
2F: External Fault (N.C., 
detected during run, alarm 
only) 
30: PID control integral 
reset 
─
31: PID control integral hold
─
32: Multi-step speed 
reference 4 
─
34: PID Soft Starter switch
─
35: PID input characteristics 
switch 
─
─
50: Nominal Speed
─
51: Intermediate Speed
─
52: Releveling Speed
─
53: Leveling Speed
─ 54:
Inspection
Operation
─ 55:
Rescue
Operation
─
56: Motor Contactor 
Feedback