Yaskawa F7 to L1000A User Manual
Page 48
 
(Header Title) Application Note
 
 
 
 
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 48 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Motor Temperature Input 
Filter Time 
L1-05 0.20
s
─
─
Momentary Power Loss 
Operation Selection 
L2-01 0 ─
─
Momentary Power Loss Ride-
Thru Time 
L2-02 * ─
─
Momentary Power Loss 
Minimum Baseblock Time 
L2-03 * ─
─
Momentary Power Loss 
Voltage Recovery Ramp Time 
L2-04 * ─
─
No corresponding parameter in L1000A.
Undervoltage Detection Level
L2-05
190 V
L2-05
190 V
380 V for a 400 class drive. 
 But if E1-01 is set lower than 400, then for set 350 V for 
L1000A. 
KEB Deceleration Time
L2-06*
0.0 s
─
─
Acceleration Time After Power 
Recovery 
L2-07 0.0
s
─
─
Momentar
y Po
wer
Loss
KEB Ride-Thru Start Output 
Frequency Reduction 
L2-08 100%
─
─
No corresponding parameter in L1000A.
Stall Prevention Selection 
during Acceleration 
L3-01 1 L3-01 1
F7 L1000A
L3-01 L3-01 
0: Disabled 
0: Disabled
1: Enabled
1: Enabled
2: Optimum Tuning
2: Optimum Tuning
Stall Prevention Level during 
Acceleration 
L3-02 150% L3-02 150%
*
*Upper limit is determined by L8-38.
Stall Prevention Limit during 
Acceleration 
L3-03 50% L3-03
─
Stall Prevention Selection 
during Deceleration 
L3-04 1 ─
─
No corresponding parameter in L1000A.
Stall Prevention Selection 
during Run 
L3-05 1 L3-05 1
F7 L1000A
L3-05 L3-05 
0: Disabled 
0: Disabled
1: Enabled (Decel Time 1)
1: Enabled (Decel Time 1)
2: Enabled (Decel Time 2)
2: Enabled (Decel Time 2)
Stall Prevention Level during 
Run 
L3-06 150% L3-06 150%
Overvoltage Inhibit Selection
L3-11
0
─
─
Stall
Pre
ven
tion Fu
ncti
on
F7 : Overvoltage Suppression 
Voltage Level 
L1000A: Overvoltage 
Suppression and Stall 
Prevention Desired DC Bus 
Voltage 
L3-12 380
V*
─
─
No corresponding parameter in L1000A.
Speed Agreement Detection 
Level 
L4-01 0.0
Hz L4-01 0.0
%
─
Speed Agreement Detection 
Width 
L4-02 2.0
Hz L4-02 4.0
%
─
Speed Agreement Detection 
Level (+/-) 
L4-03 0.0
Hz L4-03 0.0
%
─
Frequency De
te
ctio
n
Speed Agreement Detection 
Width (+/-) 
L4-04 2.0
Hz L4-04 4.0
%
─