Yaskawa F7 to L1000A User Manual
Page 51
 
(Header Title) Application Note
 
 
 
 
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 51 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Installation Selection
─
─
L8-35 2
L1000A
L8-35
0: IP00 Enclosure
2: IP00 with top cover
Automatic Torque Boost 
Selection 
─
─
L8-38 0
L1000A
L8-38
0: Disabled
3: Enabled
Reduced Carrier Frequency
─
─
L8-39
3.0
kHz
Internal Braking Transistor 
Protection 
─
─
L8-55 1
L1000A
L8-55
0: Disabled
1: Enabled
Operation Selection at Input 
Phase Loss 
─
─
L8-62 1
L1000A 
L8-62 
0: Ramp to stop 
1: Coast to stop 
2: Fast Stop 
3: Continue operation 
Oscillation Suppression
─
─
L8-77 0
─
H
ar
dw
ar
e P
rot
ec
tion
Safe Disable Operation Mode
─
─
L8-88 1
─
Hunting Prevention Function 
Selection 
n1-01 1 ─
─
No corresponding parameter in L1000A.
Hun
ting Pre
vention
Functio
n
Hunting Prevention Gain 
Setting 
n1-02 1.00
─
─
No corresponding parameter in L1000A.
Speed Feedback Detection 
Control (AFR) Gain 
n2-01 1.00 n2-01 1.00
─
Speed Feedback Detection 
Control (AFR) Time Constant 
n2-02
50 ms
n2-02
50 ms
─
Speed Feedb
ack
Detection
Contr
ol F
unction
Speed Feedback Detection 
Control (AFR) Time Constant 
2 
n2-03
750 ms
n2-03
750 ms
─
High-Slip Braking 
Deceleration Frequency Width 
n3-01 5% ─
─
High-Slip Braking Current 
Limit 
n3-02 150%
─
─
High-Slip Braking Dwell Time 
at Stop 
n3-03 1.0
s
─
─
High
Slip
Bra
king
High-Slip Braking Overload 
Time 
n3-04 40
s
─
─
No corresponding parameter in L1000A.
Feed Forward Control 
Selection 
n5-01 0 n5-01 0
F7 L1000A
n5-01 n5-01
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Feed Forward
Con
trol
Motor Acceleration Time
n5-02
*
n5-02
*
Determined by drive capacity.