Nec hp ratings for 240v normal duty models – Yaskawa GPD506/P5 to P7 User Manual
Page 21

Product Transition Guide
Appendix 1 –Ratings and Heat Loss Comparison
Page
21
of 48
NEC HP Ratings for 240V Normal Duty Models
GPD506/P5 230V Models
P7 240V Models
Variable
Torque
(n116=1)
Normal Duty
(C6-01=2)
NEC
HP
230V
NEC
Amps
GPD506/P5
Model
CIMR-P5U
Output
Amps
Fc
kHz
Overload%
VT
1 minute
P7
Model
CIMR-P7U
Output
Amps
Fc
kHz
Overload %
ND
1 minute
5 15.2 23P71 17.5
15 120
23P71 16.8 10 107
7.5 22 25P51 27
10 120 25P51 23 15 120
10 28 27P51 36
10 120 27P51 31 15 102
15 42 20111 54
10 120 20111 46.2 8 117
20 54
20151 59.4 10 117
25 68 20151 68
10 120 20181 74.8 10 114
30 80 20181 80
15 120 20221 88 10 116
40 104 20221 104
15 120 20301 115 10 120
50 130 20301 130
10 120
60 154 20371* 160 10
120
20371* 162 5 107
75 192 20451* 192 10
120 20451* 192 5 113
20551* 215 8 120
100 248 20551* 248 8
120
125 312 20751* 312 8
120
20751* 312 2 109
150 360
- -
- -
20901* 360 2 115
150 360
- -
- -
21100* 415 2 120
*Note: Optional NEMA1 kit required for NEMA1 rating. Input voltage rating is 230V on these
models.