Appendix 3- Parameter Cross Reference

Page

37

of 48

GPD506/P5 Parameter

P7 Parameter

Param

No.

Nxxx

Parameter

Name

Description or Selection

Description or Selection

Parameter

Name

Param.

No.

041


















































Multi-function
contact output 1
(terminal MA-MB-MC)






































































0: Fault
1: During run.
2: Frequency agree
3: At set frequency agree
4: Freq detect
(output freq = set freq detection level)
5: Freq detect
(output frequency = set freq detect level)
6: Overtorque detect. (N.O contact)
7: Overtorque detect. (N.C contact)
8: The base block.
9: Operation mode
10: Inverter drive ready
11: Timer function
12: Auto restart. (Fault retry)
13: OL pre-alarm (OL1,OL2)
14: Frequency reference loss
15: Closed from serial communication.
16: PID feedback loss
17: OH1 alarm

Selects the function of terminals M1 to M4.
0: During RUN 1 = Closed when a run
command is input or
the drive is outputting voltage.
1: Zero Speed = Closed when drive output
frequency is less
than Fmin (E1-09)
2: Fref/Fout Agree 1 = Closed when drive
output speed
equals the speed command within the
bandwidth of L4-02.
3: Fref/Set Agree 1 = Closed when the
drive output speed
and the speed command are equal to
the value in L4-01 within the bandwidth of
L4-02.
4: Freq Detect 1 = Closed when the drive
output speed is
less than or equal to the value in L4-01,
with hysteresis determined by L4-02.
5: Freq Detect 2 = Closed when the drive
output speed is
greater than or equal to the value in
L4-01, with hysteresis determined by L4-
02.
6: Inverter Ready = Closed when the drive
is not in a fault
state, and not in program mode.
7: DC Bus Undervolt = Closed when the
DC bus voltage
falls below the UV trip level (L2-05)
8: Base Blk 1 = Closed when the drive is
not outputting
voltage.
9: Operator Reference = Closed when the
speed command
is coming from the digital operator.
A: Remote/Auto Oper = Closed when the
run command is
coming from the digital operator.
B: Trq Det 1 N.O. - Closes when the output
current exceeds
the value set in parameter
L6-02 for more time than is set in
parameter L6-03.
C: Loss of Ref - Closes when the drive has
detected a loss
of analog speed command.
Speed command is considered lost when it
drops 90% in
0.4 seconds.
Parameter L4-05 determines drive reaction
to a loss of
speed command.

E: Fault - Closes when the drive
experiences a major fault.
F: Not Used
10: Minor Fault - Closes when drive
experiences a minor
fault or alarm.
11: Reset Cmd Active - Closes when the
drive receives a
reset command from terminals or serial
comms.
12: Timer Output - Output for independent
timer, controlled
by b4-01 and b4-02.
Used in conjunction with a multi-function
digital input.
17: Trq. Det 1 N.C. - Opens when the
output current
exceeds the value set in parameter
L6-02 for more time than is set in
parameter L6-03.

Terminal M3-M4 Function
Selection

H2-01