Protective features, Design features – Yaskawa GPD506/P5 to P7 User Manual
Page 9

Product Transition Guide
GPD506/P5 to P7
Page
9
of 48
GPD506/P5 to P7 Specification Differences
Feature
or Function
Item
Yaskawa GPD506/P5 Yaskawa P7
Performance Features
240V
0.75 to 125HP (VT)
5 to 150HP (ND2)
480V
0.75 to 500HP (VT)
5 to 500HP (ND2)
HP Range
Note: The voltage rating in
the “Item” column is
generalized. Refer to the
Service Conditions section
for rated input voltage
requirements.
600V
2 to 200HP (VT)
Available w/GPD506/P5
Not Available in P7
Overload Rating
% for Minutes
150% for 1 min (CT)
200% peak
120% for 1 min (VT)
180% peak
110% for 1 min (ND2)
150% peak
PWM Carrier Frequency
Range
See Carrier Frequency Table
See Carrier Frequency Table
Max. Output Frequency
Hz
400Hz
0 To 120Hz
Speed Range
V/f 40:1
40:1
Protective Features
Heat Sink Temperature Fault
Fault Action
Coast, Ramp, Continue
--Coast, Ramp, Continue or
Continue with reduced speed
--OH Pre-alarm level setting
Design Features
Qty of keys
7
11
Language 1
7
(w/LCD)
Copy Function
No
Yes
Keypad Design
Display
LCD display, alpha numeric, 16
char x 2 lines
LCD display, alpha numeric, 16
char x 5 lines, backlit