Appendix 3- parameter cross reference, Parameter name – Yaskawa GPD506/P5 to P7 User Manual

Page 38

Advertising
background image


Appendix 3- Parameter Cross Reference

Page

38

of 48

GPD506/P5 Parameter

P7 Parameter

Param

No.

Nxxx

Parameter

Name

Description or Selection

Description or Selection

Parameter

Name

Param.

No.

(con’t)

041





















Multi-function
contact output 1
(terminal MA-MB-MC)

























1A: Reverse Dir - Closes when the drive is
running in the
reverse direction.
1E: Restart Enabled - Closes when the
drive is performing
an automatic restart.
Automatic restart is configured by
parameter L5-01.
1F: Overload (OL1) - Closes before a
motor overload
occurs. (90% of OL1 time)
20: OH Prealarm - Closes when the Drive’s
heatsink
temperature exceeds the setting
of parameter L8-02.
38: Drive Enable - Closes when the drive
enable input is
active.
39: Waiting to Run - Closes during the time
after a run
command is issued, but the Drive is not
running due to
the time set in parameter b1-10.
3A: OH Freq Reduce
3B: Run Src Com/Opt

H2-01