2-2 Getting Started
VS-616G5 and Modbus Plus
The VS-616G5 AC drive accepts Yaskawa interface boards. Installation of a Yaskawa Modbus
Plus Communication Kit ensures the VS-616G5 is a MODICON certified ModConnect
?
partner
with direct connection to Modbus Plus.
NOTE
This interface board will only operate with a particular version of drive software.
To check software use U1-14. A “ CPF 06 ” fault will appear
on the display, if the wrong version of drive software is installed.
The Modbus Plus Communication Kit, Model No. UTC000019, provides a Modbus Plus Serial
Communication Board Interface option (the MB+ board) which allows operation, status monitoring,
and programming of a VS-616G5 drive from a MODICON Programmable Controller using the
Modbus Plus local area network.
The Modbus Plus Communication Kit is available as a factory installed option for the
VS-616G5 drive.
Yaskawa Modbus Plus Communication Kit
Each drive must have its own Modbus Plus kit installed to communicate via Modbus Plus. The
Yaskawa Modbus Plus Communication Kit consists of the following items:
- Yaskawa MB+ board.
A printed circuit board (see Figure 2-1) which mounts at connector 2CN inside the
VS-616G5.
- VS-616G5 / Modbus Plus Instruction Manual, YEA-TOA-C736-40.22.
Figure 2-1. MB+ Board
OFF ON
1
2
3
4
5
6
7
8
DIPSW
SW1
Connector P1
9 Pin “D” Shell
Pigtail
Lead
LED D2
(Green)
U21
U14
Connector 2CN
(mounted on