Yaskawa VS-616G5 Modbus Plus Communication Card User Manual

Page 108

Advertising
background image

Data Registers



A-28

Drive Parameter Registers (Read/Write) – continued

REGISTER PARAMETER

PARAMETER

PARAMETER

LIMITS / DESCRIPTION

INITIAL

(in hex)

FUNCTION

SETTING

VALUE

400h

H1-01

Multi-function Input (terminal 3)

0 to 66h

24h or 36

401h

H1-02

Multi-function Input (terminal 4)

0 to 66h

14h or 20

402h

H1-03

Multi-function Input (terminal 5)

0 to 66h

3 (or 0) (1)

403h

H1-04

Multi-function Input (terminal 6)

0 to 66h

4 (or 3) (1)

404h

H1-05

Multi-function Input (terminal 7)

0 to 66h

6 (or 4) (1)

405h

H1-06

Multi-function Input (terminal 8)

0 to 66h

8 (or 6) (1)

406h

H2-01

Multi-function Output (term. 9 & 10)

0 to 37h

0

407h

H2-02

Multi-function Output (term. 25-27)

0 to 37h

1

408h

H2-03

Multi-function Output (term. 26-27)

0 to 37h

2

409h

H3-01

Auto Speed Reference Signal

0

0 to 10 V DC

0

Level Selection (term. 13)

1

-10 to +10 V DC

40Ah

H3-02

Auto Speed Reference Signal Gain

0.0 to 1000.0%

100.0

40Bh

H3-03

Auto Speed Reference Signal Bias

-100.0 to +100.0%

0.0

40Ch

H3-04

Multi-function Analog Input 1 Signal

0

0 to 10 V DC

0

Level Selection (term. 16)

1

-10 to +10 V DC

40Dh

H3-05

Multi-function Analog Input 1 Select.

0 to 1F

0

40Eh

H3-06

Multi-function Analog Input 1 Gain

0.0 to 1000.0%

100.0

40Fh

H3-07

Multi-function Analog Input 1 Bias

-100.0 to +100.0%

0.0

410h

H3-08

Multi-function Analog Input 2 Signal

0

0 to 10 V DC

Level Selection (term. 14)

1

-10 to +10 V DC

2

2

4 to 20 mA

411h

H3-09

Multi-function Analog Input 2 Select.

1 to 1F

1F

412h

H3-10

Multi-function Analog Input 2 Gain

0.0 to 1000.0%

100.0

413h

H3-11

Multi-function Analog Input 2 Bias

-100.0 to +100.0%

0.0

414h

H3-12

Analog Input Filter Time Constant

0.00 to 2.00 seconds

0.00


Notes (for this page only):

(1) Initial Value in the parentheses are values obtained at a 3-wire initialization.