Yaskawa VS-616G5 Modbus Plus Communication Card User Manual
Page 91

Data Registers
A-11
Monitor Registers (Read only) – continued
REGISTER
FUNCTION
BIT
DESCRIPTION
(in hex)
NO.
F100h
Inverter Status
0
Run
1
Zero-Speed
2
Reverse Run
3
Reset Signal Input
4
Speed Agree
5
Drive Operation Ready
6
Minor Fault
7
Major Fault
8-15
will return zeros
F101h
Operator Status
0
oPE Error
1
not used
2
Program Mode
3
1CN Status:
4
01=JVOP132 / 00=JVOP130(std. operator) / 11=Personal Computer / 10=JVOP100
5-15
not used
F102h
oPE No.
oPE Error Code (oPE01=1, oPE02=2, oPE03=3, oPE06=6, oPE10=10, oPE11=11)
F103h
not used
-
F104h
Fault Content 1
0
Fuse Blown (FU)
1
DC Bus Undervoltage (UV1)
2
Control Power Supply Undervoltage (UV2)
3
Main Circuit Answerback (UV3)
4
Short Circuit (SC)
5
Ground Fault (GF)
6
Overcurrent (oC)
7
Overvoltage (oV)
8
Heatsink Overtemperature (oH)
9
Drive Overheat (oH1)
10
Motor Overload (oL1)
11
Drive Overload (oL2)
12
Overtorque 1 (oL3)
13
Overtorque 2 (oL4)
14
Dynamic Braking Transistor (RR)
15
Dynamic Braking Resistor (RH)