Data Registers
A-25
Drive Parameter Registers (Read/Write) – continued
REGISTER PARAMETER
PARAMETER
PARAMETER
LIMITS / DESCRIPTION
INITIAL
(in hex)
FUNCTION
SETTING
VALUE
30Eh
E2-01
Motor Rated Current
0.60 to 12.00 A
(2)
30Fh
E2-02
Motor Rated Slip
0.00 to 20.00 Hz
(2)
310h
E2-03
Motor No-Load Current
0.00 to 3.29 Amps
(2)
311h
E2-04
Number of Motor Poles
2 to 48 poles
4
312h
E2-05
Motor Line-to-Line Resistance
0.000 to 65.000 Ohms
(2)
313h
E2-06
Motor Leakage Inductance
0.0 to 30.0%
(2)
314h
E2-07
Motor Iron-core Saturation Coefficient 1
0.00 to 0.50
.50
315h
E2-08
Motor Iron-core Saturation Coefficient 2
0.00 to 0.75
0.75
316h
E2-09
Motor Mechanical Loss
0.0 to 10.0%
0.0