6.1.1 Power-up LED Sequence

When you power-up the FN10, the following occurs:

1. All LEDs, except for the Port Link LEDs, turn on for one second.

2. The Power (Pwr) LED remains on.

3. The Ready LED starts flashing.

4. After several seconds, the Port Link LEDs turn on briefly.

5. After several more seconds, the Ready LED will stay on, indicating

that the power-up diagnostics sequence is complete.

In addition, the Port Link LEDs will turn on for those ports with good
links and the Segment Status LEDs will turn on (or flash) when the
selected status condition is present.

6.1.2 Specific Power-up Tests

The power-up diagnostic tests performed on the FN10 include:

ROM checksum test

Instruction/Data memory test

Memory map test

Interrupt test

Packet memory test

Shared RAM component test

Ethernet data loopback test

NOTE

If a critical component fails diagnostics, the Ready LED will turn
off and the FN10 will attempt to reboot. If the Ready LED does
not stay on, contact Cabletron Systems Technical Support.
Refer to Section 1.2.