4. Relay Output (COM+N.O.) / (COM+N.C.)
An output to relay switch, for example, LEDs, sirens, etc.

5. Digital Input/Alarm Input
1) GND (Ground): Initial status is LOW

2) Alarm: Max. 50mA, 3.3VDC

6. Relay Output
1) N.C. (Normally Closed): Max. 1A, 24VDC or 0.2A, 110~240VAC

2) COM: (Common)

3) N.O. (Normally Open): Max. 1A, 24VDC or 0.2A, 110~240VAC

7. Power Jack
The input power is 12VDC.

Note

To ensure maximum compatibility, use only the power adapter
that came with your product. Otherwise, the product may be
damaged.

8. MIC in (audio in)
Connect a microphone to the network camera.

9. Line Out (Audio Out)
Connect a loud speaker to the network camera. This is for voice alert and two-way
audio.

2.1.3 Installation

1. Fix IR camera in a desired location with stand.

2. Plug in Ethernet Cable into RJ-45 connector (LAN port).

3. Connect the attached power adapter to camera and plug in this adapter into

power outlet.

4. Connect Video BNC connector to a TV set if necessary (to check camera viewing

angle and focus).

5. Done.