4 wiring the power inputs – PLANET IGS-504HPT User Manual

Page 16

Advertising
background image

16

2.1.4 Wiring the Power Inputs

The 6-contact terminal block connector on the top panel of Industrial Gigabit PoE+
Switch is used for two DC redundant powers input. Please follow the steps below
to insert the power wire.

1. Insert positive/negative DC power wires into contacts 1 and 2 for Power 1, or 5

and 6 for power.

1 2 3 4 5 6

V1- V1+ V2 - V2+

2. Tighten the wire-clamp screws for preventing the wires from loosening.

1

2

3

4

5

6

Power 1

Fault

Power 2

-

+

-

+

Note

The wire gauge for the terminal block should be in the range
between 12 and 24 AWG.

Advertising