6. Cable Connection Parameters

The wiring details are as shown below:
100FX Fiber Optic Cables:

Standard

Fiber Type

Cable Specification

100BASE-FX (1310nm)

Multi-mode

50/125μm or 62.5/125μm

Single-mode

9/125μm

100BASE-BX-U
(TX :1310/RX :1550nm)
100BASE-BX-D
(TX :1550/RX :1310nm)

Single-mode

9/125μm

1000X Fiber Optic Cables:

Standard

Fiber Type

Cable Specification

1000BASE-SX
(850nm)

Multi-mode

50/125μm or 62.5/125μm

1000BASE-LX
(1310nm)

Multi-mode

50/125μm or 62.5/125μm

Single-mode

9/125μm

Wiring Distances:

Standard

Fiber

Diameter

(micron)

Modal Bandwidth

(MHz * km)

Max. Distance

(meters)

1000BASE-SX Multi-mode

62.5
62.5
50
50

100
200
400
500

220
275
500
550

1000BASE-LX

Multi-mode

62.5
50
50

5
4
5

550

Single-mode 9

N/A

5000

1000BASE-ZX Single-mode 9

N/A

~70,000

Note

The single-mode port (1000BASE-LX port) of the IGS-624HPT
provides an additional margin allowing 10/20/30/40/50/70/120 km
Gigabit Ethernet to link to single mode fiber.