Fast/Gigabit Ethernet standard requires Category 5 UTP for 100Mbps 100BASE-TX.
10BASE-T networks can use Cat3, 4, 5 or 1000BASE-T uses 5/5e/6 UTP (see table
below). Maximum distance is 100 meters (328 feet). The 100BASE-FX/1000BASE-
SX/LX SFP slot is used as LC connector with optional SFP module. Please see table
below and know more about the cable’s specification.

Port Type

Cable Type

Connector

10BASE-T

Cat3, 4, 5, 2-pair

RJ45

100BASE-TX

Cat5 UTP, 2-pair

RJ45

1000BASE-T

Cat5/5e/6 UTP, 4-pair

RJ45

100BASE-FX

50/125µm or 62.5/125µm multi-mode
9/125µm single-mode

LC (multi/single mode)

1000BASE-SX/
LX

50/125µm or 62.5/125µm multi-mode
9/125µm single-mode

LC (multi/single mode)

Any Ethernet devices like hubs/PCs can be connected to the Industrial Gigabit
PoE+ Switch by using straight-through wires. The four 10/100/1000Mbps ports are
auto-MDI/MDI-X and can be used on straight-through or crossover cable.

2.1.6.1 Installing the SFP transceiver

The sections describe how to insert an SFP transceiver into the IGS-624HPT SFP
slot.

The SFP transceivers are hot-pluggable and hot-swappable. You can plug in and
out the transceiver to/from any SFP port without having to power down the
Industrial Gigabit PoE+ Switch as the Figure 2-3 appears.

MGB / MFB Series
Transceiver

Figure 2-3: Plug-in the SFP transceiver

Approved PLANET SFP Transceivers

PLANET Industrial Gigabit PoE+ Switch supports both single mode and multi-mode
SFP transceivers. The following list of approved PLANET SFP transceivers is correct
at the time of publication: