PLANET IGS-504HPT User Manual

Page 22

Advertising
background image

22

3. Check whether the fiber-optic cable type matches with the SFP transceiver

model.

To connect to MFB-FX SFP transceiver, use the multi-mode fiber cable with

one side being the male duplex LC connector type.

To connect to MFB-F20/F40/F60/FA20/FB20 SFP transceiver, use the single-

mode fiber cable with one side being the male duplex LC connector type.

Connecting the fiber cable
1. Insert the duplex LC connector on the network cable into the SFP transceiver.
2. Connect the other end of the cable to a device – switches with SFP installed, to

fiber NIC on a workstation or a media converter.

3. Check the LNK/ACT LED of the SFP slot of the switch/converter. Ensure that the

SFP transceiver is operating correctly.

2.1.6.2 Removing the Transceiver Module

1. Make sure there is no network activity by consulting or checking with the

network administrator. Or through the management interface of the switch/
converter (if available), disable the port in advance.

2. Remove the Fiber Optic Cable gently.
3. Turn the latch of the MGB/MFB module to a horizontal position.
4. Pull out the module gently through the latch.

1

2

MGB / MFB Series
Transceiver

Figure 2-4: Pulling out from the transceiver

Note

Never pull out the module without pulling the latch or the push
bolts on the module. Directly pulling out the module with force
could damage the module and the SFP module slot of the Industrial
Gigabit Ethernet Switch.

Advertising