ProSoft Technology MVI69E-MBTCP User Manual
Page 105

MVI69E-MBTCP ♦ CompactLogix Platform
Diagnostics and Troubleshooting
Modbus TCP/IP Enhanced Communication Module
User Manual
ProSoft Technology, Inc.
Page 105 of 150
May 20, 2015
6.5.4 MBTCP Client-Specific Errors
Code
Description
-33
Failed to connect to server specified in command
-36
MBTCP command response timeout
-37
TCP/IP connection ended before session finished
Note: If an error code is reported that is not listed above, check with the documentation of the end
device. Device-specific error codes can be produced by the end device.
6.6
Connecting to the Module’s Webpage
The module’s internal web server provides access to module version and status
information, as well as the ability to set the date and time, reboot the module, and
download firmware upgrade to the module. Enter the assigned IP address of the
module into a web browser or use the following steps in PCB.
1 In the Diagnostics window in ProSoft Configuration Builder, click the S
ET
U
P
C
ONNECTION
button.
2 In the Connection Setup dialog box, click B
ROWSE
D
EVICE
(
S
)
to start the
ProSoft Discovery Service.