Installing and Configuring the Module

MVI46-DFCM ♦ SLC Platform

DF1 Communication Module

ProSoft Technology, Inc.

Page 23 of 103

October 20, 2008

2.2.2 Port 1 Setup

Database in SLC

Database in MVI46-DFCM

File

M0 Offset

File

Register

Content

Description

N10:6 7

N32:10 5010 Enable This parameter defines if this port

will be utilized. If the parameter is
set to 0, the port is disabled. A
value of 1 will enable the port.

N10:7

8

N32:11

5011

Type

This parameter defines if the port
will emulate a master or slave
device. Enter 0 to emulate a
master device and 1 to emulate a
slave device.

N10:8

9

N32:12

5012

Local Station
ID

This parameter specifies the local
station ID for all DF1 messages
sent from this master port. A
value of 255 is not permitted as
this is the broadcast address.
Valid value in the range of 0 to
254.

N10:9

10

N32:13

5013

Protocol

0=full duplex, 1=half-duplex

N10:10

11

N32:14

5014

Termination
Type

This parameter specifies the error
checking for all DF1 messages.
0=BCC, 1=CRC

N10:11

12

N32:15

5015

Baud Rate

This is the baud rate to be used
on the port. Enter the baud rate
as a value

Baud
Rate

Parameter Value

110

110

150

150

300

300

600

600

1200

12 or 1200

2400

24 or 2400

4800

48 or 4800

9600

96 or 9600

14,400

14, 114 or 14400

19,200

19, 192 or 19200

28,800

28, 288 or 28800

38,400

38, 384 or 38400

57,600

57 or 576

115,200 115 or 1152

N10:12

13

N32:16

5016

Parity

This is the Parity code to be used
for the port. The coded values are
as follows: 0=None, 1=Odd,
2=Even, 3=Mark and 4=Space.

N10:13

14

N32:17

5017

Data Bits

This parameter sets the number
of data bits for each word used by
the protocol. Valid value in the
range of 5 to 8.