14 Global Settings

Sequential

18 . MIDI Param Send:

Off, CC, NRPN—

Changes to the values of front

panel controls are transmitted via MIDI as Non-registered Parameter

Number (NRPN) controllers or as Continuous Controllers (CC). Trans-

mission of parameters can also be turned off.

NRPNs are the preferred method of parameter transmission, since they cover

the complete range of all parameters, while CCs are limited to a range of 128.

19 . MIDI Param Receive:

Off, CC, NRPN—

Sets the method by which

parameter changes are received via MIDI. As with transmission, NRPNs

are the preferred method.

20 . MIDI Control On:

Off, On—

When On, the synth will respond to

MIDI controllers, including Pitch Wheel, Mod Wheel, Pedal, Breath,

Volume, and Expression.

21 . MIDI Sysex On:

On, Off—

Sets whether MIDI System Exclusive data

will be received or ignored.

22 . MIDI Sysex Cable:

MIDI, USB—

Sets the port, MIDI or USB, by

which System Exclusive data will be transmitted and received.

23 . MIDI Out Select:

Off, MIDI, USB, All—

Sets the port(s) by which

MIDI data will be transmitted.

24 . MIDI Program Send:

Off, On—

When On, the synth will transmit

MIDI Program Change and other SysEx messages to the MIDI Out.

25 . MIDI Program Receive:

Off, On—

When On, the synth will respond

to received MIDI Program Change and other SysEx messages.

26 . MIDI Arp Notes:

Off, On—

When On, the synth’s Arpeggiator outputs

MIDI note numbers. You can use this feature to drive other MIDI-

equipped devices such as synthesizers and drum machines

.

27 . Arp Beat Sync:

Off, Quantize—

When set to

quantize

, Arpeggiator

note playback occurs only on the beat (relative to the current clock divide

setting) regardless of when you press a key on the keyboard

.

Advertising