CHAPTER 4: INSTRUCTION SET

LDB %BA,[%ir]+

Load location [ir reg.] into BA reg. and increment ir reg.

2 cycles

Function:

A

[ir], B

[ir + 1], ir

ir + 2

Loads the 2-word data in the data memory into the BA register. The content of the data
memory addressed by the ir register (X or Y) is loaded into the A register as the low-order 4
bits, and the content of the next address is loaded into the B register as the high-order 4 bits.
The ir register (X or Y) is incremented by 2 words.

Code:

Mnemonic

MSB

LSB

LDB %BA,[%X]+

1

1

1

1

1

1

1

0

1

1

0

0

0

1FD8H

LDB %BA,[%Y]+

1

1

1

1

1

1

1

0

1

1

0

1

0

1FDAH

Flags:

E

I

C

Z

Mode:

Src: Register indirect
Dst: Register direct
Extended addressing: Invalid

LDB %BA,%EXT

Load EXT reg. into BA reg.

1 cycle

Function:

BA

EXT

Loads the content of the EXT register into the BA register.

Code:

Mnemonic

MSB

LSB

LDB %BA,%EXT

1

1

1

1

1

1

1

0

1

0

1

1

X

1FD6H, (1FD7H)

Flags:

E

I

C

Z

Mode:

Src: Register direct
Dst: Register direct
Extended addressing: Invalid