PC relative jump instructions

Program memory

0000H

FFFFH

xxxxH

xxxxH-127

JR sign8

xxxxH+128

0000H

FFFFH

xxxxH-1

xxxxH

xxxxH-32767

LDB %EXT,imm8

JR sign8

xxxxH+32768

0000H

FFFFH

xxxxH JR %A

xxxxH+16

A=0

xxxxH+1

:
A=15

xxxxH+16

0000H

FFFFH

xxxxH JR %BA

xxxxH+256

BA=0

xxxxH+1

:
BA=255

xxxxH+256

0000H

FFFFH

JP %Y

Y

Branch destination

absolute address

0000H

FFFFH

xxxxH JR [addr6]

xxxxH+16

[addr6]=0

xxxxH+1

:
[addr6]=15

xxxxH+16

Indirect jump instruction

0000H

FFFFH

003FH

addr6

Program memory

Program memory

Program memory

Program memory

Data memory

Program memory

In the extended addressing mode,

this instruction can branch the
entire 64K program memory.

Fig. 2.2.3.1 Operation of jump instructions

• Absolute call instruction (CALZ)

The absolute call instruction "CALZ imm8" calls a subroutine within addresses 0000H to 00FFH. A
subroutine start address (absolute address) should be specified to imm8. When the call instruction is
executed, the PC value (address of the next instruction) is saved into the stack for return, then it
branches to the specified address.
Generally common subroutines that are called from two or more modules are placed in this area when
the program is developed as multiple modules.

Example:

CALZ 0x50

...Calls the subroutine located at the address 0050H

See Section 2.3.3, "Stack and stack pointer" for stack.

• PC relative call instructions (CALR)

The PC relative call instruction adds the relative address specified in the operand to the PC that has
indicated the next address, and calls a subroutine started from that address. It permits relocatable
programming.
The relative address to be specified in the operand is same as the PC related jump instruction.
The PC value (address of the next instruction) is saved into the stack before branching.

(1) Instructions with a signed 8-bit immediate data sign8 that specifies a relative address

CALR sign8

This instruction branches the program sequence with the sign8 specified in the operand as a
signed 8-bit relative address. The range that can be branched is from the next instruction address -
128 to +127. A value within the range from -128 to +127 should be used if specifying a value for
calling in the assembler. Generally branch destination labels such as "CALR LABEL" are used, and
they are expanded into the actual address by the assembler.