TROUBLESHOOTING (continued)

Symptom and Checklist (continued)

Symptoms

Checklist

Page

Intermittent interference

Check if the source of interference is shielded correctly.

Move these kinds of electrical devices away from the unit.

Normal picture, but no sound

Check the volume level.

Check audio settings on HDMI source must be set to PCM.
Check if the

button has been pressed or not.

Check the connections to external equipment.
Check if input signal is HDMI or DVI by pressing

INFO

button, remember

DVI must be connected on HDMI 2 and audio must be input by separate.

25

No picture - normal sound

Check the value level of “Brightness” and “Contrast” in “Picture Menu”.

35

,

40

The remote control does not work.

Check if the batteries are installed correctly.

The batteries might be exhausted. Replace them with new ones.

Remove all obstructions from in front of the sensor window on the unit.

18

,

19

Picture Frezze and/or the buttons on

both the remote control and control
panel do not work.

Unplug and connect after 5 minutes the power cord or turn Main switch Off

and On after 5 minutes both A/V Center and UT Monitor.

Hold down the Reset button on the UT Monitor control panel for over a

second.

16

Normal picture but no color-normal sound

Check the connections to external equipment.

20

~

23

No picture

UT Monitor Indicating lamp → Off

Check if the power cord is plugged into the socket securely for UT Monitor.

Check if the main switch is on for UT Monitor.

15

,

24

No picture

UT Indicating lamp → Orange

It means that UT monitor is in “Power

Save mode”.

Check if the A/V Center to UT Monitor cable is connected correctly and

securely.

Check if the power of the A/V Center is ON.

Refer to “When the Following Messages Appears on the Screen”.

45

,

13

No picture

UT Monitor indicating lamp → Green

Check if the signal cable is connected correctly and securely.

Check if the A/V Center to UT Monitor cable is connected correctly and

securely.

13

The top of the unit and surface of the

panel heat up.

This may occur if you use the unit for a long time. Turn off the main power

to the unit for a while. Please note that this is not a malfunction.

Some screen display aspects are not

possible.

Check the signal status by pressing the

INFO

button on the remote control.

The available screen display aspect is different depending on the current

signal status.

26

42

,

43

Image cannot be displayed from HDMI

input.

Check if the cables are connected correctly.

Turn off A/V Center and HDMI source, then turn A/V Center on first then HDMI

source.

Check the output format of the equipment.

(Please refer to “CONNECTION” and “Recommended Signal List”.)

48

~

50

Turns Off by itself

Check or ensure Timer settings are not activated.

Picture may “block” or freeze when

watching a digital channel.

Check signal strength and noise levels under ”Signal Meter”

No sound from TV Optical Out when

using HDMI devices

Change Digital Output selection.•
As an option, use audio optical output from HDMI source device directly to

separate Audio Amplifier

Some digital programming looks blurry

during fast changing scenes..

This is normal and its due regular digital compression scheme, please note

this is not a malfunction.