7 sensor setup menu, 8 nmea setup menu – Furuno GP-1600F User Manual

Page 75

Advertising
background image

5 – 7

5.7 SENSOR SETUP menu

The SENSOR SETUP menu provides for selection and calibration
of speed and temperature sensors (optional equipment).

Keying sequence: [MENU ESC] [0] [5]

SENSOR SETUP

SPD SENSOR

STW

SOG

TEMP SENSOR OWN

NMEA

SPD CALIB +00%(-50 ~ +50)
TEMP CALIB +00.0 °C
DEPTH CALIB +0.0 ft

▼▲ :Cursor :+/-
ESC:Esc

Figure 5-9 SENSOR SETUP menu

SENSOR SETUP menu description

SPD SENSOR: Select speed input source; navaid or internal.

TEMP SENSOR: Select device (option) which feeds temperature
data; external or internal.

SPD CALIB: Enter offset to correct speed data.

TEMP CALIB: Enter offset to correct water temperature data.

DEPTH CALIB: Enter offset to correct depth.

5.8 NMEA SETUP menu

This menu selects output data format and type of external device
connected to the GP-1600F.

Keying sequence: [MENU ESC] [0] [6]

NMEA SETUP

FORMAT

183V1.5

183V2.0

EXT DEVICE

REM

PILOT

▲▼ts:Cursor ESC:Esc

Figure 5-10 NMEA SETUP menu

NMEA SETUP menu description

FORMAT: Select the format of data output to external equipment.

EXT DEVICE: Select external device connected to the GP-1600F.

Advertising