Line engineering, M3900 set power consumption, Line eng ineering – Meridian Audio M3900 User Manual

Page 109

Advertising
background image

Environmental and safety considerations

Page 109 of 174

M3900 Series Meridian Digital Telephones Description, Installation and Administration

Line engineering

The M3900 Series Meridian Digital Telephones use twisted pair wiring on
transmission lines determined by the rules in Digital Telephone Line
Engineering
(553-2201-180). The maximum acceptable loop length is 1067
m. (3500 ft), assuming24 AWG (0.5 mm) standard twisted wire with no
bridge taps. A 15.5 dB loss at 256 kHz defines the loop length limit. Longer
lengths are possible, depending on the wire’s gauge and insulation.

M3900 set power consumption

CAUTION

Use only the line cord provided with the telephone. A line cord
designed for another telephone can cause damage to the equipment.

Table 14
M3900 set power consumption

M3901

M3902

M3903

M3904

M3905

Idle

29.3

37.3

42.5

31.5

15.02

H/F Nominal

N/A

45.7

48.7

37.5

N/A

H/F
Maximum

N/A

64.3

59.7

46.4

N/A

DBA Idle

N/A

N/A

N/A

39.29

15.31

DBA H/F
Nominal

N/A

N/A

N/A

45.9

N/A

DBA H/F

N/A

N/A

N/A

52

N/A

Maximum 2
KBA Idle

N/A

N/A

N/A

33.42

14.98

Note: All measurements are in milli-amps.

Advertising