Appendix A: Flash Download procedure

553-3001-216 Standard

5.00

January 2002

STAT the hardware

1

Load LD 137 and get the status of the hard disks.

Note: Be sure the hard disks are synchronized. If not, synchronize
before proceeding.

LD 137
STAT

Get the status of the hard disks

TEST CMDU Performs hard and floppy disk test.
****

exit program

2

Load LD 135 and get the status of the CPs, CNIs, and memories.

LD 135
STAT CPU
Get the status of both CPs and memory
STAT CNI Get the status of all configured CNIs

Check that Core 0 is active

1

Be sure Core 0 is active. If Core 1 is active, make Core 0 active:

LD 135
STAT CPU
Get status of the CPOS
SCPU

Switch to Core 0 (if necessary)

****

exit program

Split the Cores

1

From the active side, split the cores:

LD 135
SPLIT
Enter Split on the active core
Allow the former active side to INIT before continuing
****

exit program

The system is now in split mode.