Synchronize the hard disks, Perform a data dump – Meridian Audio M3900 User Manual

Page 152

Advertising
background image

Page 152 of 174

Appendix A: Flash Download procedure

553-3001-216 Standard

5.00

January 2002

Synchronize the hard disks

1

Load LD 137 and synchronize the hard disks. Synchronization can take
up to 50 minutes. To be sure that the contents of IODU/C 1 are copied to
IODU/C 0, verify that IODU/C 0 is disabled.

LD 137
STAT

Get the status of the IODU/C and redundancy

SYNC

Enter “Yes” to synchronize disks. Wait until the memory

synchronization successfully completes before continuing. TEST CMDU
Performs hard and floppy disk test.

2

Get the status of the CMDU's and be sure CMDU 0 is active. Switch if
necessary.

STAT

Get the status of IODU/C and redundancy

SWAP Switch CMDU if necessary

STAT CMDU Get the status of the IODU/Cs. Be sure the same IODU/C
and CPU are active.

****

exit program

Perform a data dump

1

Load the Equipment Data Dump Program (LD 43). At the prompt, enter:

LD 43 to load the program

2

When EDD000 appears on the terminal, enter:

EDD to begin the data dump

3

When DATABASE BACKUP COMPLETE or DATADUMP
COMPLETE appears on the terminal, enter:

**** to exit the program

The PSDL file has now been installed on your switch.

CAUTION
If the data dump is not successful, do not continue;
contact your technical support organization. A data
dump problem must be corrected before proceeding.

Advertising