Configure the M3900 Series Meridian Digital Telephone

Page 71 of 174

M3900 Series Meridian Digital Telephones Description, Installation and Administration

FTNR

(NO)

YES

<CR>

TN range restriction option for Flash Download
NO = no TN restriction (default)
YES = specify TN range

FSTN

l s c u

c u

Starting terminal number for Flash Download

Prompt appears only if FTNR = YES.

FETN

l s c u

c u

Ending terminal number for Flash Download

Prompt appears only if FTNR = YES.

FDNR

(NO)

YES

<CR>

DN range restriction option for Flash Download
NO = no DN restriction (default)
YES = specify DN range

FDDN

c d1 d2

<CR>

Flash Download Prime Directory Number range

Prompt appears only if FDNR = YES.

c = Customer number (0-99)

d1 = starting Prime DN

d2 = ending Prime DN

FRCE

(NO)

YES

<CR>

System-wide Flash Download control option
NO = Conditional (default).System-wide Flash Download (via FDLS
in LD 32) applies only to an M3900 series set whose flash firmware
version is different from the version currently found on the system
disk
YES = Forced.Force System-wide Flash Download to all of the
specified M3900 series sets regardless of their current flash firmware
versions.

Note 1: Use this option with caution! Once the download tree is built (i.e.,
after executing FDLS in LD 32), this option automatically reverts to NO.

Note 2: This option is not applicable to reporting.

FVER

v

<CR>

Flash firmware version specified for full report

v = Flash firmware version (0-99)
If 0, report all versions (default).

Note: This option is applicable to reporting only (via FSUM ALL in LD 32).

LD 97 – Configure parameters for System-wide Flash Download (Part 2 of 2)

Prompt

Response

Description