Install software on core/net 1 – Meridian Audio M3900 User Manual

Page 145

Advertising
background image

Appendix A: Flash Download procedure

Page 145 of 174

M3900 Series Meridian Digital Telephones Description, Installation and Administration

2

Verify that IODU/C 0 is active. You may need to switch IODU/Cs.

LD 137

STAT

Get the status of IODU/C

SWAP Switch IODU/Cs if necessary
****

exit program

3

Connect a terminal to the CPSI port in Core/Net 1 to J25 of the I/O panel
at the back of the Core/Net. Be sure it is configured as follows. The
recommended baud rate is 9600, to be the same as the CPSI port.

7 data bits, 1 stop bit, Space parity, Full duplex, XON protocol

4

Place CP 0 in Maintenance by settingthe MAINT/NORM switch to
MAINT.

5

In Core/Net 1, disable the CNI cards by settingthe ENB/DIS faceplate
switches to DIS

Install software on Core/Net 1

1

Place the CP Install disk that corresponds with the installed CP card type
into the IODU/C in Core/Net 1.

2

Install the CD-ROM into the CD drive:

a.

Press the button on the CD-ROM drive to open the CD-ROM disk
holder.

b.

Place the CD-ROM disk into the holder with the disk label showing.

c.

Use the four tabs to secure the CD-ROM drive.

d.

Press the button again to close the CD-ROM disk holder (do not
push the holder in by hand).

3

In Core/Net 1, perform the followingthree steps in uninterrupted
sequence:

a.

Press and hold the MAN RST button on the CP card.

b.

Set the MAINT/NORM switch on the CP card to MAINT.

c.

Release the MAN RST button.

A sysload begins (cold start). Wait for the Main Menu to appear on the
terminal before proceeding.