Furuno – Furuno GP-3500 User Manual

Page 191

Advertising
background image

FURUNO

GP-3500

SP - 2

E4421S01C

Range and bearing to cursor intersection,

Water temperature and water depth (sensor data required)

4 INTERFACE

4.1

Number of ports

Input: 3 ports, Output: 2 ports

4.2

Input data

IEC 61162-1, NMEA0183 Ver1.5/2.0

Sentences

BWC, BWR, DPT, DBT, DBK, DBS, GGA, GLC, GLL, GNS, GTD,

HDT, HDG, HDM, MTW, RMA, RMB, RMC, RTE, TLL, TTM, VHW,

VTG,

ZDA

4.3

Output data

IEC 61162-1, NMEA0183 Ver1.5/2.0

Sentences

AAM, APB, BOD, BWC or BWR, DPT or DBT, GGA, GLL, GNS,

GTD, HDG, HDT, MTW, MWV, RMA, RMB, RMC, RTE, TTM,

VHW, VTG, WPL, XTE, ZDA

4.4

I/O data

RS-232C for PC

5 POWER

SOURCE

5.1

Display unit

12-24 VDC: 1.5-0.8 A

6 ENVIRONMENTAL

CONDITIONS

6.1

Ambient temperature

Antenna unit: -25

to + 70

Display unit: -15

to + 55

6.2

Relative humidity

95% (40

)

6.3

Waterproof

Antenna unit: IPX6

(IEC60529)

Display unit: IPX2 (external monitor attached: IPX0)

6.4 Vibration

IEC

60945

7 COATING

COLOR

7.1

Display unit

Chassis: Munsell 2.5GY5/1.5, Panel: N3.0

7.2

Antenna unit

N9.5 (white)

8

COMPASS SAFE DISTANCE

8.1 Display

unit

Standard:

0.6 m

Steering: 0.4 m

Advertising