background image

Camera Setup

Selecting Video Output Options

6

6-9

Selecting Video Output Options

Using the video port and video cable, you can display the live, paused, or
saved images on a TV, video projector, or video monitor. You can also record
images on a video recorder.

Video output can be set to NTSC, PAL, or disabled.

Note

Disable the video output function when not in use to save
battery power.

To select NTSC or PAL signal and enable/disable video output:

1. Plug the video cable (the end with the cylindrical noise suppressor) into

the camera video port; plug the other end of the cable into the TV,
projector, monitor, or video recorder.

2. Tap F on the camera.

3. Use the MOUSE controller to position the pointer over Camera Settings

on the popup menu.

4. Tap E.

5. Position the pointer over the Locale tab and tap E.

6. Position the pointer over either the PAL or NTSC video signal radio

button and select. The black circle indicates setting is enabled.

7. Position the pointer over the Power tab and select.

8. Position the pointer over the Video Output Enabled button and select. A

check mark indicates function is enabled. When not in use, disable this
function to conserve battery power.

9. Tap the TRIGGER button to accept setting change and return to scan

target mode.