CenturyStack 8100 Managed Hub

Module 8103-03-X

Module 8103-03-X provides a two port internal bridge for bridging
10Mbps and 100Mbps segments and 100BASE-FX distance extender with
SC type connectors and fiber cable. The internal bridge must be enabled or
disabled with on board jumpers before installation. The external distance
extender is always enabled. Module flow-control (backpressure) can be
enabled or disabled by setting the on board jumpers before installation. The
default settings are as follows:

Bridge Function setting: Internal enabled (Default)

Backpressure setting: Disabled (Default)

Module 8103-03-X Bridge Jumpers
The default jumper setting of the Module 8103-03-X is internal bridge
disabled. The external distance extender is always enabled. To enable the
internal bridge, change the jumpers (JP3 & JP5~JP7) from 1&2 to 2&3.

Jumper JP1—Duplex Jumper (JP1)

1&2 = half duplex

2&3 = full duplex

Jumpers JP3 & JP5~JP7

1&2 connected = internal bridge is disabled (Default)

2&3 connected = internal bridge is enabled

Module 8103-03-X Backpressure Jumpers
The default jumper setting for backpressure is disabled. To enable the
backpressure function for the external port and internal 100Mbps segment,
change JP2 jumper to 2&3. To enable the backpressure function for the
internal bridge change JP8 jumper to 2&3.

Jumpers JP2, JP8

1&2 = disabled (Default)

2&3 = enabled

3 Ports

Switch Module

FDX
COL

LINK

TX

RX

2

NOTE: JP2 is used to control the distance extender port and internal
100Mbps-segment backpressure function. JP8 is used to control internal
bridge backpressure function.