CenturyStack 8100 Managed Hub

Group Reset
All, some or none of the group’s function can be changed by selecting one
of these options:

NOTE: The selected option takes effect after SAVE is executed.

No Reset: None of these are reset.

Reset All: The function logic and counters of the group will
be reset. This is identical to cold restart.

Reset Function Logic Only:

The function logic of the group

will be reset. The counters will be held static and will not be
reset. This reset operation will reset the link status of each
port to ‘Link Down’. That will cause a Link Status Change
event to be raised.

Reset Counters Only:

The counters of each port will be

reset to 0, but the function logic will be held static and will
not be reset.

Group Name: The name assigned to this hub.

Group Last Change Notify

Enable: Sends out a trap when the value of this field
changes.

Disable: Does not send out a trap when the value of this
field changes.

To change the setting of a given group:

1. Select the group by number.

2. Set the new value to the Group Admin State.

3. Set reset request to the Group Reset field.

4. Type in the name of the Group Name field.

5. Set Group Last Change Notify field.

6. Select <Save>.