CenturyStack 8100 Managed Hub

Suspend: Indicates that the active ports are disabled and the
redundant link function is temporarily suspended until you
set its state to enable.
NOTE: The suspend state does not cause the port to be
switched over.

Invalid: Purge the configuration of a redundant link pair
from the system database.

Return-to-primary: Selecting this option and pressing enter
re-assigns the primary link as the active link again. A trap is
sent to the trap receivers if the status of the redundant link is
enable. If the status is suspend, then the link pair is
reactivated, but no trap is sent.

Configuring Link Pairs

1. Select a Link Pair. (1-24) Use NEXT PAGE to select pairs

13 through 24.

2. Enter the Primary Link Group (1 to 6).

3. Enter the Primary Link Port (1 to 12/24).

4. Enter the Secondary Link Group (1 to 6).

NOTE: You can configure and save the Secondary Link
Group and the Primary Link Group as the same hub,
however, this will be of no use in the event of a hub failure.

5. Enter the Secondary Link Port (1 to 12/24).

6. Enable the Link Switch Over Notify. (Optional)

7. Enable the Status.

8. Select <Save> to update the new Linked Pair. Repeat these

steps for each Link Pair.