Table 1.2 Special register list (Continued)

No. Name

Meaning

Details

Set by

(When set)

Remark

SD16
SD17
SD18
SD19

• Individual information corresponding to the diagnostic error (SD0) is stored.
• The error individual information type can be judged by SD4 (individual

information category code).
5: Parameter No.

SD20

No.

Meaning

SD21

SD16

Parameter

No.

SD22

SD23

SD24

SD17

to

SD26

Empty

SD25

0401H

:Base

setting

0406H

:Motion slot setting

0E00H

:Multiple CPU setting (Number of Multiple CPU's)

0E01H

:Multiple CPU setting (Operation mode/Multiple CPU

synchronous startup)

E008H

:Multiple CPU high speed transmission area setting

(CPU specific send range setting/ (System area))

E009H/E00AH :Multiple CPU high speed transmission area setting

(Automatic refresh setting)

E00BH

:Synchronous

setting

13: Parameter No./CPU No.

No.

Meaning

SD16

Parameter

No.

SD17

CPU No.(1 to 4)

SD18

to

SD26

Empty

SD26

Error individual
information

Error individual
information

SD53

AC/DC DOWN
counter No.

Number of times
for AC/DC DOWN

• Every time the input voltage fails to or below 85[%] (AC power)/65[%] (DC

power) the rating during calculation of the Motion CPU module, the value is
incremented by 1 and stored in BIN code.

SD60 Fuse

blown

No.

Module No. with
blown fuse

• The lowest station I/O No. of the module with the blown fuse is stored.

S (Occur an error)

• The CPU switch status is stored in the following format.

B15

B12 B11

B8 B7

B4 B3

B0

1)

2)

Not used

1) CPU switch status

0: RUN
1: STOP

2) Memory card switch

Always OFF

SD200 Status of switch

Status of CPU
switch

• The CPU operating status is stored as indicated in the following figure.

B15

B12 B11

B8 B7

B4 B3

B0

1)

2)

1) Operating status of CPU

0: RUN
2: STOP

2) STOP cause

(Note) Priority is earliest first

0: RUN/STOP switch
4: Error

SD203

Operating status
of CPU

Operating status
of CPU

S (Main processing)