1 overview, 2) motion modules – MITSUBISHI ELECTRIC MOTION CONTROLLERS Q172DCPU User Manual

Page 35

Advertising
background image


1 - 18

1 OVERVIEW

(2) Motion modules

(a) Installation position of Q172DEX

(Note-1)

is only the main base unit.

It cannot be used on the extension base unit.

(b) Q172DLX/Q173DPX can be installed on any of the main base unit/

extension base unit.

(c) Q172DLX/Q172DEX

(Note-1)

/Q173DPX cannot be installed in CPU slot and I/O

slot 0 to 2 of the main base unit. Wrong installation might damage the main
base unit.

(d) Q172EX(-S1/-S2/-S3)/Q172LX/Q173PX(-S1) for Q173HCPU(-T)/

Q172HCPU(-T)/Q173CPUN(-T)/Q172CPUN(-T)/Q173CPU/Q172CPU
cannot be used.

(e) Be sure to use the Motion CPU as the control CPU of Motion modules

(Q172DLX, Q172DEX

(Note-1)

, Q173DPX, etc.) for Motion CPU. They will not

operate correctly if PLC CPU is set and installed as the control CPU by
mistake. Motion CPU is treated as a 32-point intelligent module by PLC
CPU of other CPU.

(Note-1) : Q172DEX can be used in SV22. It cannot be used in SV13.

Advertising
This manual is related to the following products: