1 overview, B) motion sfc performance specifications – MITSUBISHI ELECTRIC MOTION CONTROLLERS Q172DCPU User Manual

Page 24

Advertising
background image


1 - 7

1 OVERVIEW

(b) Motion SFC Performance Specifications

Item Q173DCPU/Q172DCPU

Code total
(Motion SFC chart + Operation control
+ Transition)

543k bytes

Motion SFC program capacity

Text total
(Operation control + Transition)

484k bytes

Number of Motion SFC programs

256 (No.0 to 255)

Motion SFC chart size/program

Up to 64k bytes (Included Motion SFC chart comments)

Number of Motion SFC steps/program

Up to 4094 steps

Number of selective branches/branch

255

Number of parallel branches/branch

255

Motion SFC program

Parallel branch nesting

Up to 4 levels

Number of operation control programs

4096 with F(Once execution type) and FS(Scan execution type)

combined. (F/FS0 to F/FS4095)

Number of transition programs

4096(G0 to G4095)

Code size/program

Up to approx. 64k bytes (32766 steps)

Number of blocks(line)/program

Up to 8192 blocks (in the case of 4 steps(min)/blocks)

Number of characters/block

Up to 128 (comment included)

Number of operand/block

Up to 64 (operand: constants, word device, bit devices)

( ) nesting/block

Up to 32 levels

Operation control program

Calculation expression/bit conditional expression

Operation control program
(F/FS)
/
Transition program
(G)

Descriptive
expression Transition program

Calculation expression/bit conditional expression/

comparison conditional expression

Number of multi execute programs

Up to 256

Number of multi active steps

Up to 256 steps/all programs

Normal task

Execute in main cycle of Motion CPU

Fixed cycle

Execute in fixed cycle

(0.88ms, 1.77ms, 3.55ms, 7.11ms, 14.2ms)

External
interrupt

Execute when input ON is set among interrupt module QI60

(16 points).

Event task
(Execution
can be
masked.)

PLC interrupt

Execute with interrupt instruction (D(P).GINT) from PLC CPU.

Execute specification

Executed
task

NMI task

Execute when input ON is set among interrupt module QI60

(16 points).

Internal relays

(M)

8192 points

Link relays

(B)

8192 points

Annunciators (F)

2048

points

Special relays

(SM)

2256 points

Data registers

(D)

8192 points

Link registers

(W)

8192 points

Special registers

(SD)

2256 points

Motion registers

(#)

8736 points

Coasting timers

(FT)

1 point (888µs)

Number of devices
(Device In the Motion CPU
only)
(Included the positioning
dedicated device)

Multiple CPU area devices

(U \G)

Up to 14336 points usable

(Note)

(Note): Usable number of points changes according to the system settings.

Advertising