Appendices – MITSUBISHI ELECTRIC MOTION CONTROLLERS Q172DCPU User Manual

Page 161

Advertising
background image


APP - 26

APPENDICES

APPENDIX 4 Differences Between Q173DCPU/Q172DCPU and Q173HCPU/Q172HCPU

APPENDIX 4.1 Differences Between Q173DCPU/Q172DCPU and Q173HCPU/Q172HCPU

Common differences to each mode are shown in Table 4.1.
Refer to "APPENDIX 4.3 Differences of each mode" for characteristic differences to
each mode.
And, refer to "APPENDIX 4.2 Comparison of devices " for detailed differences of
devices.

Table 4.1 Differences Between Q173DCPU/Q172DCPU and Q173HCPU/Q172HCPU

Item Q173DCPU/Q172DCPU

Q173HCPU/Q172HCPU

Peripheral I/F

Via PLC CPU (USB/RS-232)

USB/SSCNET

External battery

Demand

Add Q6BAT at continuous power failure for 1
month or more.

Forced stop input

• Use EMI terminal of Motion CPU module.
• Use device set by forced stop input setting in

the system setting.

• Use device set by forced stop input setting in

the system setting.

Multiple CPU high speed
transmission memory for data
transfer between CPU modules

Included —

Internal relays (M)

8192 points

Latch relays (L)

None (Latch for M is possible by latch setting)

Total 8192 points

Special relays (M)

256 points

Special relays (SM)

2256 points

Special registers (D)

256 points

Special registers (SD)

2256 points

Motion registers (#)

8736 points

8192 points

D

evi

ce

Multiple CPU area devices
(U \G)

Up to 14336 points

Motion dedicated PLC instructions

D(P).DDRD, D(P).DDWR, D(P).SFCS,
D(P).SVST, D(P).CHGT, D(P).CHGV,
D(P).CHGA, D(P).GINT

S(P).DDRD, S(P).DDWR, S(P).SFCS,
S(P).SVST, S(P).CHGT, S(P).CHGV,
S(P).CHGA, S(P).GINT

Interlock

condition

Multiple instructions are executable continuously
without interlock condition by the self CPU high
speed interrupt accept flag from CPU .

:CPU No.

Interlock condition by the to self CPU high speed
interrupt accept flag from CPU is necessary.

Motion modules

Q172DLX, Q172DEX, Q173DPX

Q172LX, Q172EX, Q173PX

System setting

• QnUD(H)CPU is set as CPU No. 1.
• Only Multiple CPU high speed main base unit

(Q38DB/Q312DB) can be used as main base
unit.

• Motion modules cannot be installed to I/O 0 to 2

slot.

• QnUD(H)CPU is set to CPU No. 1.
• Q3 B can be used as a main base unit.
• Motion modules can be mounted to I/O 0 to 2

slot.

Latch clear

Remote operation

L.CLR switch

RUN/STOP

Remote operation, RUN/STOP switch

RUN/STOP switch

ROM operation

• ROM writing is executed with mode operated

by RAM/ mode operated by ROM.

• ROM writing can be executed for the data of

MT Developer.

Rom writing is executed with installation mode/
mode written in ROM.